Product Description

Membrane Type: Cross Linked Fully Aromatic Polyamide Composite
Construction: Spiral Wound Element
Application: Drinking Water

Model Diameter Inches Salt Rejection % Product Flow Rate gpd (l/h)
HM 1810-LPE-60 1.8 95% 60 (9.45)

Test Conditions

Feed Water Pressure: 75 psi (5.2 kg/cm2)
Feed Water Temperature: 77oF (25oC)
Feed Water Concentration: 500 ppm softened tap water
Recovery Rate: 25%
Feed Water pH: 6.5 – 7

Notes:
Minimum salt rejection is 90%
Permeate flow may vary +/-20%

Dimensions

Operating Limits

Maximum Operating Pressure: 150 psi (10.5 kg/cm2)
Maximum Operating Temperature: 104oF (40oC)
Maximum Cleaning Temperature: 104oF (40oC)
Feed Water Chlorine Concentration: Not Detectable
Feed Water pH Range, Continuous Operation: 2 – 11
Maximum Feed Water SDI (15 Minute Test): SDI < 5
Maximum Feed Turbidity: NTU < 1

Operating Information

  1. Follow instructions mentioned on the caution sticker placed on product packaging.
  2. The customer is fully responsible for the effects of chemicals that are incompatible with the elements.
  3. For element loading, use only the recommended silicon lubricant. The use of petroleum based lubricant or vegetable based oils may damage the element irreversibly.
  4. Membranes show some resistance to short-term attack by chlorine (Hypochlorite). Continuous exposure should be avoided as it may damage the membrane.

Impact of Temperature on Permeate Flow (Keeping Recovery and Pressure Constant)

ENQUIRE NOW

    * All Fields are Mandatory