HM UF PVDF 70

HM UF 70 PVDF High Performance Ultrafiltration Module

MODEL Surface Area (m2) Dimensions (mm) Weight (kg)
A B C D
HM UF 70 PVDF 70 2220±1 1915±1 395±1 200±1 60
  • PVDF based hollow fiber membranes have long lifetime due to their high mechanical strength and chemical resistance.
  • The capacity of clean water production is higher due to modification of membranes
    which enhances the hydrophilicity of membrane.

Membrane Specifications

Model HM UF 70 PVDF
Type Hollow Fiber Ultrafiltration
Material Modified Polyether Sulphone
Nominal Pore Size nm (µ) 30 (0.03)
MWCO Dalton 100,000
Fiber Bore Diameter (Inner) mm 0.8
Fiber Bore Diameter (Outer) mm 1.4
Housing & End Cap (MOC) UPVC

Module Data

Membrane Surface Area (Active) m2 70
Outer Diameter Housing mm 250
Nozzels mm DN50 Victaulic End
Empty Weight With End caps kgs 60

Operational Data

Mode of Operation Out to In (Dead End / Cross Flow)
Operating Flux Range gfd (lmh) 26 – 105 (45 – 180)
Operating Temperature °C 1 — 40
Feed Pressure Operating Range bar 2.0 to 2.5
Feed Pressure Maximum @ 25°C bar 5
Trans membrane Pressure bar 0.4 – 2
pH Range Operation 2.0 – 11.0
Maximum NaOCl mg/l 2000
Particle Dimension µ < 200
Total Suspended Solid (TSS) ppm 50 (max 80)
Max Feed Turbidity NTU 50 (max 250)
Oil & Grease Nil

Performance Details

Filtrate Flow Range gpm (m³/hr) 8.8 – 35 (2 – 8)
Filtrate SDI ≤ 2.5
Filtrate Turbidity NTU ≤ 0.1
Bacteria Reduction log 6
Virus Reduction log 4

Process Data

Backwash Flux gfd (lmh) 59 – 88 (100 – 150)
Backwash Pressure bar 2.5 max
Air scouring flowrate Nm³/h 12 – 15 (max 20)
Chemically Enhanced Backwash (CEB):
NaOH mg/l 500
HCL mg/l 1000
NaOCl mg/l 1000

Note: *Backwash / CEB / CIP frequency & duration shall be as per the design based on the feed water source, quality & fluctuations